"title": "LEARN | Understanding UPS systems",
"nid": "451",
"body": "\u003Cp\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za\u0022\u003E\u003Cimg alt=\u0022UPS\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u00220d43037a-18ab-4dfc-9994-5b691ce67426\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/ups-pic.jpg\u0022 class=\u0022align-center\u0022 /\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Cp\u003EIf you\u2019re in the market for a UPS, read our quick article to learn UPS basics, the type of protection they offer, and what important considerations you should keep front of mind when selecting a UPS\u2026\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhat is a UPS?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003EAn uninterruptible power supply or uninterruptible power source (UPS) is a device that:\u003Cbr /\u003E\n1. Provides back-up power when utility power fails, either long enough for critical equipment to shut down gracefully so that no data is lost, or long enough to keep required loads operational until a generator comes online.\u003C/p\u003E\n\u003Cp\u003E2. Conditions incoming power so that all-too-common sags and surges do not damage sensitive electronic gear.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhat protection does a UPS offer?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003EUPS Systems have three different levels of protection that they offer:\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003E1. Offline UPS systems\u003C/strong\u003E\u003Cbr /\u003E\n- acts as a battery back-up\u003Cbr /\u003E\n- predominantly for residential use\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003E2. Line interactive UPS system\u003C/strong\u003E\u003Cbr /\u003E\n- offer automatic voltage regulation and power surge protection\u003Cbr /\u003E\n- maintains the power output to equipment at normal levels\u003Cbr /\u003E\n- takes over when the power goes out\u003Cbr /\u003E\n- the amount of output from a line interactive UPS depends on its kVA Rating\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003E3. Online double conversion UPS system\u003C/strong\u003E\u003Cbr /\u003E\n- the highest level of UPS protection\u003Cbr /\u003E\n- used to protect equipment that is vital to business operations such as IT suites and data centres\u003Cbr /\u003E\n- have a zero changeover time as they provide a constant, pure sine wave electrical supply to equipment\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhat to consider when selecting a UPS?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003EIt is important to ask the right questions when it comes to deciding on a back-up power supply. Here are three important questions you should consider:\u003C/p\u003E\n\u003Cp\u003E\n\u003Cstrong\u003E1. What equipment do you need a UPS to protect?\u003C/strong\u003E\u003Cbr /\u003E\n- consider how important the equipment is that you want to protect, common items include security systems and servers\u003Cbr /\u003E\n- you may need to back-up expensive equipment, whereas only a safe shut down is essential for other equipment\u003Cbr /\u003E\n- also consider the duration for which the equipment will require UPS power\u003C/p\u003E\n\u003Cp\u003E\n\u003Cstrong\u003E2. What is the equipment\u2019s current electrical draw?\u003C/strong\u003E\u003Cbr /\u003E\n- consider how much power is drawn from each of the items your UPS will need to protect\u003C/p\u003E\n\u003Cp\u003E\n\u003Cstrong\u003E3. How much space do you have?\u003C/strong\u003E\u00A0\u003Cbr /\u003E\n- UPS systems can be range from oversized and cumbersome, to petite and compact. It all depends on the type and quantity of equipment you need to protect, and you may be limited to the amount of space you can allocate the storage of UPS systems.\u003C/p\u003E\n\u003Cp\u003E\u00A0\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EConclusion\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003EFor businesses to operate optimally, a back-up power solution should definitely be considered. Turn to a UPS system for the dual protection of offering back-up power, and conditioning incoming power to your sensitive or critical equipment.\u003C/p\u003E\n\u003Cp\u003ENeed a back-up power solution for your facility? \u003Ca href=\u0022mailto:hello@magnetgroup.co.za\u0022\u003E\u003Cstrong\u003EChat\u003C/strong\u003E\u003C/a\u003E to our experts now!\u003C/p\u003E\n\u003Cp\u003E\u00A0\u003C/p\u003E\n",
"created": "Nov 2020",
"terms": "Electrical, Solar, Back-Up Power, Education"
},
{
"title": "PRODUCT NEWS | Save production time with Marechal\u0026#039;s EVO",
"nid": "450",
"body": "\u003Cp\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za\u0022\u003E\u003Cimg alt=\u0022Evo\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u0022c927e9b6-478f-4bce-ad38-2ced938f60cc\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/Evo.png\u0022 class=\u0022align-center\u0022 /\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003ESafety, innovation and technology \u2013 these words have become synonymous with the Marechal Electric brand and their extensive portfolio of low voltage electrical industrial plug\u00A0and socket outlets. These words also accurately capture the essence of EVO, \u003Cstrong\u003Ethe world\u0027s first separable switch disconnector\u2026\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EA customer\u2019s pain point:\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EWhen it comes to industrial electrical equipment, it\u2019s not a simple process to connect or disconnect a plug and socket outlet under load. There are several protocols to follow, such as:\u003C/p\u003E\n\u003Cp\u003E- calling out a qualified electrician\u003Cbr /\u003E\n- ensuring the electrician and his team are wearing the necessary PPE\u003Cbr /\u003E\n- electrician can then locate the isolator\u003Cbr /\u003E\n- isolate the isolator\u00A0and test using\u00A0the correct multi-meter tool to\u00A0ensure there is no load/power\u003Cbr /\u003E\n- once deemed safe, the plug and socket can then be disconnected for purposes such as performing maintenance\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EPlug and play with the EVO\u2026\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EMarechal\u2019s EVO \u201CTwist \u0026amp; Switch Technology\u201D affords you the ease and convenience of disconnecting and connecting under load without all the hassle, saving you valuable production time!\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EThis innovative product is the world\u0027s first separable switch-disconnector, combining the functions of a switch, isolator and connector\u00A0in a single device.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EThe EVO can be separated in two parts (supply and load) to allow the replacement of the electrical equipment it supplies, without unwiring or disconnecting the upstream power supply.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhat makes the EVO safe and reliable?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003E1. Butt contact silver nickel spring loaded pressurised system\u003Cbr /\u003E\n- A modern switchgear technology, as opposed to pin and sleeve technology inherited from domestic accessories, dating back to the early ages of electricity\u003C/p\u003E\n\u003Cp\u003E2. Crimped Braids \u0026amp; Elastic Lock Terminals\u003Cbr /\u003E\n- Provides contact performance and tolerances superior to traditional \u2018pin and sleeve\u2019 contacts\u003Cbr /\u003E\n- Can withstand overloads, vibration, corrosion and variations of temperature\u003C/p\u003E\n\u003Cp\u003E3. Safety Shutter\u003Cbr /\u003E\n- The base is fitted with an interlocked safety shutter that prevents the access to live contacts\u003Cbr /\u003E\n- This shutter only unlocks at the time of the connection of the plug into its base\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EA strong and durable separable switch disconnector for all your installations\u2026\u003C/strong\u003E\u003Cbr /\u003E\nTurn to the EVO for 100% assured safety.\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022https://www.youtube.com/watch?v=j0P5ffTIhB0\u0022\u003E\u003Cstrong\u003EWATCH\u003C/strong\u003E\u003C/a\u003E a quick video to view this incredible device.\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/download/marechal-evo-magnet.pdf\u0022\u003E\u003Cstrong\u003EDOWNLOAD\u003C/strong\u003E\u003C/a\u003E the EVO brochure to learn more.\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za\u0022\u003E\u003Cstrong\u003ECHAT\u003C/strong\u003E\u003C/a\u003E to us for a Marechal Electric solution for your facility now!\u003C/p\u003E\n",
"created": "Nov 2020",
"terms": "Electrical, Products, Marechal Electric"
},
{
"title": "READ | Understanding the latest edition of SANS 10142-1",
"nid": "449",
"body": "\u003Cp\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za\u0022\u003E\u003Cimg alt=\u0022sans\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u0022e556c362-1533-4bcd-8994-db5f7aaf245b\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/johan-db-newsletter_0.jpg\u0022 class=\u0022align-center\u0022 /\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EREAD | The latest edition of SANS 10142-1 has been published!\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003EThe third edition of SANS10142-1 (The wiring of premises Part 1: LV installations) has recently been published. In this article, we\u2019ll outline why the standard was revised, along with the most important changes made.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhat is SANS 10142-1? \u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003EThis South African standard is referenced for all forms of low voltage electrical installations. The Occupational Health and Safety Act (OHS Act) deems it compulsory for electrical installations to comply with all requirements of the standard.\u003C/p\u003E\n\u003Cp\u003EMoreover, the OHS Act stipulates that a registered professional (Master Installation Electrician, installation electrician or an electrical tester for single phase) issue a Certificate of Compliance for an electrical installation, in line with the requirements of the standard.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhat brought about the revision to SANS 10142-1?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003EAside from requirements being out of date, the standard was intentionally revised to better align it to international norms. International technologies used in South Africa need to be verified and aligned with our local conditions.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWho should pay particular attention to the changes? \u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003EYou should definitely familiarise yourself with the updated standard if you are an electrician, tester, electrical contractor, engineer, technician and the like. Educational bodies and people working in the electrical industry at large should all be well-acquainted with the changes as briefly outlined below.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhat are the major changes that have been made?\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli\u003EIntroduction of arc fault detection devices in electrical installations.\u003C/li\u003E\n\u003Cli\u003EIntroduction of an annex to provide information on how to perform neutral earth resistance tests.\u003C/li\u003E\n\u003Cli\u003EModification of resistance of earth continuity conductor requirements.\u003C/li\u003E\n\u003Cli\u003EIntroduction of lightning protection requirements, as well as an informative annex which refers to SANS 10313 and SANS 62305 series.\u003C/li\u003E\n\u003Cli\u003EModification of electrical installation test reports in hazardous locations.\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp\u003E\nClick \u003Ca href=\u0022https://ecasa.co.za/technical/latest-edition-3-of-the-wiring-code-sans-10142-1-published/\u0022\u003E\u003Cstrong\u003Ehere\u003C/strong\u003E\u003C/a\u003E to read more of the changes implemented\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhere can you get the latest SANS 10142-1 from? \u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003EThe latest standard can be purchased from the SABS store.\u003C/p\u003E\n\u003Cp\u003EClick \u003Ca href=\u0022https://store.sabs.co.za/pdfpreview.php?hash=f11e2bbb2a20be3945abb37416d3168464321f17\u0026amp;preview=yes\u0022\u003E\u003Cstrong\u003Ehere\u003C/strong\u003E\u003C/a\u003E to preview the document.\u003C/p\u003E\n\u003Cp\u003E\u00A0\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022https://ecasa.co.za/technical/latest-edition-3-of-the-wiring-code-sans-10142-1-published/\u0022\u003E\u003Cstrong\u003ESource:\u003C/strong\u003E\u003Cbr /\u003E\necasa.co.za\u003Cbr /\u003E\n\u003Cem\u003E\u0022Latest edition (3) of the wiring code (SANS 10142-1) published\u0022\u003C/em\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Cp\u003E\u003Cem\u003E\u003Ca href=\u0022https://ecasa.co.za/technical/latest-edition-3-of-the-wiring-code-sans-10142-1-published/\u0022\u003EErika Van Zyl\u003Cbr /\u003E\n14 September 2020\u003C/a\u003E\u003C/em\u003E\u003C/p\u003E\n",
"created": "Nov 2020",
"terms": "Electrical, Education"
},
{
"title": "LEARN | Understanding Earth Grounding",
"nid": "446",
"body": "\u003Cp\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/download/fluke-earth-ground-testing-range.pdf\u0022\u003E\u003Cimg alt=\u0022Substation\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u0022426ba239-82a2-4f5c-88f4-47bc50b23f3b\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/energy-article.jpg\u0022 class=\u0022align-center\u0022 /\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EGrounding is so much more important than most people think!\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EGrounding errors can cause electrical shock, fires, equipment damage, and power quality problems.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EIn this article, we\u2019ll give you a basic understanding of grounding and outline its importance.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhat is a ground?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EThe US National Electrical Code (NEC) Article 100 defines a ground as: \u201Ca conducting connection, whether intentional or accidental, between an electrical circuit or equipment and the earth, or to some conducting body that serves in place of the earth\u201D.\u003C/p\u003E\n\u003Cp\u003EGrounding actually encompasses two different subjects: earth grounding and equipment grounding.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EEarth grounding is an intentional connection from a circuit conductor, usually the neutral, to a ground electrode placed in the earth. Equipment grounding ensures that operating equipment within a structure is grounded properly.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EThese two grounding systems must be kept separate except for connections between the two systems. This prevents differences in voltage potential from a possible flashover from lightning strikes.\u003C/p\u003E\n\u003Cp\u003EThe purpose of a ground is to provide a safe path for the dissipation of fault currents, lightning strikes, static discharges, and electromagnetic interference (EMI).\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhat affects the grounding resistance?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EWhen installing grounding systems, focus on ways to reduce the ground resistance. Here are ways to effectively lower ground resistance:\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003E1. Driving ground electrodes deeper\u003C/strong\u003E\u003Cbr /\u003E\nThe resistance level can generally be reduced by an additional 40% by doubling the length of the ground electrode.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003E2. Multiple ground electrodes\u003C/strong\u003E\u003Cbr /\u003E\nMore than one electrode is driven into the ground and connected in parallel to lower the resistance.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003E3. Increased diameter of the ground electrode\u003C/strong\u003E\u003Cbr /\u003E\nAlthough this may have very little effect, it does help lower resistance. For example, you could double the diameter of a ground electrode and your resistance would only decrease by 10%.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003E4. Complex ground system design\u003C/strong\u003E\u003Cbr /\u003E\nComplex grounding systems consist of multiple ground rods, connected, mesh or grid networks, ground plates, and ground loops. These systems are typically installed at power generating substations, central offices, and cell tower sites. Complex networks dramatically increase the amount of contact with the surrounding earth and lower ground resistances.\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/download/fluke-earth-ground-testing-range.pdf\u0022\u003E\u003Cimg alt=\u0022Ground system design\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u0022975dd84b-b29e-4f1e-8f5e-825b67590c2f\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/Ground%20system%20design.jpg\u0022 class=\u0022align-center\u0022 /\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhy ground? \u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EPoor grounding contributes to downtime. Moreover, a lack of good grounding is also dangerous and increases the risk of equipment failure.\u003C/p\u003E\n\u003Cp\u003EWithout an effective grounding system, you could be exposed to the risk of:\u003Cbr /\u003E\n- electric shock\u003Cbr /\u003E\n- instrumentation errors,\u003Cbr /\u003E\n- harmonic distortion issues,\u003Cbr /\u003E\n- power factor problems\u003Cbr /\u003E\n- and a host of possible intermittent dilemmas\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhat to look for?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EAddressing grounding problems requires testing the grounding system and then retesting after any corrections or modifications.\u003Cbr /\u003E\nPay particular attention to:\u003Cbr /\u003E\n- corrosion in ground rods and their connections due to exposure to moisture, salt and fluctuating temperatures.\u003Cbr /\u003E\n- a year-to-year increase in resistance of 20 percent\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EThese red flags should be investigated immediately.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003EIt\u0027s good to be grounded\u2026\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003EIf fault currents have no path to the ground through a properly designed and maintained grounding system, they will find unintended paths that could include people.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003ETherefore, structures with properly grounded electrical systems are critical to the safety of people and equipment, giving current from a lightning strike or utility overvoltage a safe path to earth.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EWhether simple or complex, grounding systems require periodic testing to ensure their readiness.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003ELearn more about grounding! Click \u003Ca href=\u0022https://www.magnetgroup.co.za/download/fluke-webinars.pdf\u0022\u003E\u003Cstrong\u003Ehere\u003C/strong\u003E\u003C/a\u003E to register for free educational webinars!\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003ETurn to Fluke for their comprehensive earth ground testing products. Click \u003Ca href=\u0022https://www.magnetgroup.co.za/download/fluke-earth-ground-testing-range.pdf\u0022\u003E\u003Cstrong\u003Ehere\u003C/strong\u003E\u003C/a\u003E to download a brochure.\u00A0\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003ENeed a grounding solution? Click \u003Ca href=\u0022mailto:hello@magnetgroup.co.za\u0022\u003E\u003Cstrong\u003Ehere\u003C/strong\u003E\u003C/a\u003E to chat to our electrical experts now!\u003C/p\u003E\n",
"created": "Nov 2020",
"terms": "Electrical, Education"
},
{
"title": "PRODUCT NEWS | Brady\u0026#039;s range of solutions for workplace safety",
"nid": "444",
"body": "\u003Cp\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za\u0022\u003E\u003Cimg alt=\u0022Brady logo\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u00226abd94cd-6c3b-42b9-abaa-6241b7dcde69\u0022 height=\u0022109\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/brady_0.jpg\u0022 width=\u0022373\u0022 class=\u0022align-center\u0022 /\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EMagnet is an authorised channel partner for Brady\u003C/strong\u003E - global leaders in safety solutions.\u003C/p\u003E\n\u003Cp\u003EBrady\u00A0identifies and protects products, people, and premises with high performance labels, industrial label printers, software, safety \u0026amp; facility identification, spill control, Lockout Tagout solutions and more!\u00A0\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EBrady helps you create and maintain safer work environments and comply with regulatory standards. \u003C/strong\u003ETheir high-performance materials clearly identify products, components and other assets, even in the most extreme conditions.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EBrady offers solutions for:\u003C/strong\u003E\u003Cbr /\u003E\n- Area and logistics marking\u003Cbr /\u003E\n- Safety signage\u003Cbr /\u003E\n- Lockout Tagout and Scafftag\u003Cbr /\u003E\n- Labels sleeves and tags\u003Cbr /\u003E\n- Printers and scanners\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EBrady has an extensive range of Industrial Printers:\u003C/strong\u003E\u003Cbr /\u003E\nBrady\u0027s\u00A0bench-top printers offer a full range of capabilities and options to provide high quality, cost-effective printing on a complete line of labelling materials.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003E\u003Ca href=\u0022https://www.youtube.com/watch?v=ooQjnaxRyvw\u0022\u003EWATCH\u003C/a\u003E\u00A0\u003C/strong\u003Ea quick video to learn more about making your workplace visual with Brady.\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za\u0022\u003E\u003Cstrong\u003ECHAT\u003C/strong\u003E\u003C/a\u003E to our experts for a Brady solution for your facility!\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022https://www.youtube.com/watch?v=ooQjnaxRyvw\u0022\u003E\u003Cimg alt=\u0022Brady workplace video\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u00229b7f2cca-81bb-407f-85a4-8bc46327f8a1\u0022 height=\u0022354\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/brady-youtube-thumb%20copy_0.jpg\u0022 width=\u0022629\u0022 class=\u0022align-center\u0022 /\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Cp\u003E\u00A0\u003C/p\u003E\n",
"created": "Nov 2020",
"terms": "Electrical, Products, Brady"
}
]
If you’re in the market for a UPS, read our quick article to learn UPS basics, the type of protection they offer, and what important considerations you should keep front of mind when selecting a UPS…
What is a UPS?
An uninterruptible power supply or uninterruptible power source (UPS) is a device that:
1. Provides back-up power when utility power fails, either long enough for critical equipment to shut down gracefully so that no data is lost, or long enough to keep required loads operational until a generator comes online.
2. Conditions incoming power so that all-too-common sags and surges do ...
Safety, innovation and technology – these words have become synonymous with the Marechal Electric brand and their extensive portfolio of low voltage electrical industrial plug and socket outlets. These words also accurately capture the essence of EVO, the world's first separable switch disconnector…
A customer’s pain point:
When it comes to industrial electrical equipment, it’s not a simple process to connect or disconnect a plug and socket outlet under load. There are several protocols to follow, such as:
- calling out a qualified electrician
- ensuring the electrician and his team are weari...
READ | The latest edition of SANS 10142-1 has been published!
The third edition of SANS10142-1 (The wiring of premises Part 1: LV installations) has recently been published. In this article, we’ll outline why the standard was revised, along with the most important changes made.
What is SANS 10142-1?
This South African standard is referenced for all forms of low voltage electrical installations. The Occupational Health and Safety Act (OHS Act) deems it compulsory for electrical installations to comply with all requirements of the standard.
Moreover, the OHS Act stipulates that a registered pr...
Grounding is so much more important than most people think!
Grounding errors can cause electrical shock, fires, equipment damage, and power quality problems.
In this article, we’ll give you a basic understanding of grounding and outline its importance.
What is a ground?
The US National Electrical Code (NEC) Article 100 defines a ground as: “a conducting connection, whether intentional or accidental, between an electrical circuit or equipment and the earth, or to some conducting body that serves in place of the earth”.
Grounding actually encompasses two different subjects: earth grounding and ...
Magnet is an authorised channel partner for Brady - global leaders in safety solutions.
Brady identifies and protects products, people, and premises with high performance labels, industrial label printers, software, safety & facility identification, spill control, Lockout Tagout solutions and more!
Brady helps you create and maintain safer work environments and comply with regulatory standards. Their high-performance materials clearly identify products, components and other assets, even in the most extreme conditions.
Brady offers solutions for:
- Area and logistics marking