HTTP_CONNECTION:Keep-Alive HTTP_ACCEPT:text/html,image/png,image/jpeg,image/pjpeg,image/x-xbitmap,image/svg+xml,image/gif;q=0.9,*/*;q=0.1 HTTP_ACCEPT_ENCODING:gzip, identity;q=0.9 HTTP_ACCEPT_LANGUAGE:en, * HTTP_HOST:api.dev.ecatonline.co.za HTTP_IF_MODIFIED_SINCE:Wed, 14 Feb 2024 09:36:06 GMT HTTP_MAX_FORWARDS:10 HTTP_REFERER:http://www.magnet.co.za/news.html?page=14 HTTP_USER_AGENT:Mozilla/4.5 (compatible; HTTrack 3.0x; Windows 98) HTTP_X_FORWARDED_HOST:www.magnet.co.za HTTP_X_ORIGINAL_URL:/news.html?page=24 HTTP_X_FORWARDED_FOR:169.0.58.185:54958 HTTP_X_ARR_SSL:3072|256|C=US, O=Let's Encrypt, CN=R3|CN=magnet.co.za HTTP_X_ARR_LOG_ID:a72a77b7-a8eb-4239-ad66-21f76efea45e
[ { "title": "LEARN | Condition Monitoring pt 5 - Residual Current Monitoring", "nid": "502", "body": "\u003Cp\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/solutions-electrical/index.php\u0022\u003E\u003Cimg alt=\u0022RCM\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u0022f5deea5f-34f9-4757-bbcb-21fdd0d11e71\u0022 height=\u0022185\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/Control%20Cabinet%201_RZ.jpg\u0022 width=\u0022285\u0022 class=\u0022align-center\u0022 /\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003EResidual Current Monitoring in an Industrial Environment\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EWe\u0027re wrapping up\u00A0our series on \u003Ca href=\u0022https://www.magnetgroup.co.za/news.php?type=articles\u0026amp;name=LEARN--Condition-Monitoring-part-4\u0022\u003E\u003Cstrong\u003ECondition Monitoring\u003C/strong\u003E\u003C/a\u003E, by discussing Residual Current Monitoring (RCM) as an essential system to implement in any industrial environment. By monitoring the state of the electrical system in a facility, RCM\u00A0assists in detecting faults early \u2013 reducing downtime and saving money.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003ECatch up on previous articles in our Condition Monitoring series:\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cfont face=\u0022arial, helvetica, sans-serif\u0022\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/news.php?type=articles\u0026amp;name=LEARN--Condition-Monitoring-part-1\u0022\u003E\u003Cstrong\u003EPart 1:\u003C/strong\u003E\u003C/a\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/news.php?type=articles\u0026amp;name=LEARN--Condition-Monitoring-part-1\u0022\u003E\u003Cstrong\u003EThe benefits of a condition monitoring system\u003C/strong\u003E\u003C/a\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/news.php?type=articles\u0026amp;name=LEARN--Condition-Monitoring-part-1\u0022\u003E\u00A0\u003C/a\u003E\u003C/font\u003E\u003Cfont color=\u0022#000000\u0022 face=\u0022arial, helvetica, sans-serif\u0022\u003E \u00A0\u003C/font\u003E\u003Cbr /\u003E\n\u003Cfont face=\u0022arial, helvetica, sans-serif\u0022\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/news.php?type=articles\u0026amp;name=LEARN--Condition-Monitoring-part-2---Vibration\u0022\u003E\u003Cstrong\u003EPart 2: Vibration monitoring\u003C/strong\u003E\u003C/a\u003E\u003C/font\u003E\u003Cbr /\u003E\n\u003Cfont face=\u0022arial, helvetica, sans-serif\u0022\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/solutions-electrical/news.php?type=articles\u0026amp;name=LEARN--Condition-Monitoring-part-3---Vibration-continued\u0022\u003E\u003Cstrong\u003EPart 3: Vibration monitoring continued\u003C/strong\u003E\u003C/a\u003E\u003C/font\u003E\u003Cbr /\u003E\n\u003Cfont face=\u0022arial, helvetica, sans-serif\u0022\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/news.php?type=articles\u0026amp;name=LEARN--Condition-Monitoring-part-4\u0022\u003E\u003Cstrong\u003EPart 4: A\u003C/strong\u003E\u003C/a\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/news.php?type=articles\u0026amp;name=LEARN--Condition-Monitoring-part-4\u0022\u003E\u003Cstrong\u003En overview of motor circuit analysis\u003C/strong\u003E\u003C/a\u003E\u003C/font\u003E\u003Cbr /\u003E\n\u00A0\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EIn this fifth and final article in the series, we outline Residual Current Monitoring by discussing what it entails, and the advantages of implementing it in your facility.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003EWhat is residual current?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EResidual current is an electric current that flows briefly in the circuit after the voltage has been reduced to zero. This is due to the momentum of charge carriers.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003EWhat is Residual Current Monitoring?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EResidual Current Monitoring (RCM) is implemented in an earthed electrical systems to continuously monitor the fault of residual current levels. It monitors the network continuously for faults, and generates an alarm when these occur.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003EExamples of situations that may generate an alarm are:\u003C/strong\u003E\u003C/p\u003E\n\u003Col\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EInsulation damage or degradation\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EWiring errors\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003ENeutral-to-ground faults\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EConnection of defective devices\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EMinute leakage currents that are unable to be picked up by fuses or circuit breakers\u003C/li\u003E\n\u003C/ol\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003EWhat are the advantages of Residual Current Monitoring?\u003C/strong\u003E\u003C/p\u003E\n\u003Col\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EEnsures preventative maintenance can occur before an expensive breakdown happens.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EProvides protection for the whole electrical system as well as other electrical devices that are installed.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003ECollection of valuable data from the electrical system.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EPreventative electrical safety for both man and machine.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EReduces operating costs and cost risks.\u003C/li\u003E\n\u003C/ol\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003EWhat is the significance of RCM in industrial environments?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003E1. Optimised Maintenance:\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EInformation is obtained immediately by centralised or distributed alarm messages.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EPlanning of time and personnel resources can be done efficiently and effectively through complete documentation and precise location of the fault.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EThe use of remote diagnostics and administration will ensure preventative intervention over a LAN network.\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003E2. Increase Fire Protection:\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EDetection of potential fire hazards caused by high fault currents.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EIndicating a neutral conductor overload or interruption at an early stage, thus preventing material damage.\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003E3. Higher Operational and System Safety:\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EProvides preventative safety, for both man and machine, against the hazard of electrical current.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EMonitors insulation deterioration continuously.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EDetects potential faults when commissioning new electrical installations.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EAlarm messages are sent for signalling or switching off the system.\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003E4. Improved Economic Efficiency:\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EReduction of maintenance and operating expenses.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EUnplanned system downtimes can be avoided through information obtained at early stages.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EIncrease in productivity due to operational reliability.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EDetection of weak points in the electrical system will assist in investment decisions.\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003E5. Comprehensive Information:\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EInformation is displayed clearly on Liquid Crystal Display (LCD).\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EEasily integrated into a facility management system.\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003EWhat is a Residual Current Monitoring device?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EA Residual Current Monitor is used to measure residual current. If there is an increase in the residual current, it can be detected and reported at an early stage. As seen in the figure below, the residual current monitor cannot independently interrupt the supply line. A differential current is measured and is sent out by a suitable interface. These devices also have one or more relay outputs that can be used to control circuit breakers.\u003C/p\u003E\n\u003Cp\u003E\u003Cfigure role=\u0022group\u0022 class=\u0022caption caption-img align-center\u0022\u003E\n\u003Ca href=\u0022mailto:hello@magnetgroup.co.za?subject=Electrical Enquiry\u0022\u003E\u003Cimg alt=\u0022RCM\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u00224e6a0ebb-b6f7-4995-aa76-003c8ccc8ba6\u0022 height=\u0022286\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/RCM.jpg\u0022 width=\u0022270\u0022 /\u003E\u003C/a\u003E\n\u003Cfigcaption\u003EWiring of a RCM device\u003C/figcaption\u003E\n\u003C/figure\u003E\n\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EWhat components are used in a Residual Current Monitoring system?\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EA typical residual current monitoring system, as seen in the image below, consists of the current measuring device, relays, circuit breakers and a display.\u003C/p\u003E\n\u003Cp\u003E\u003Cfigure role=\u0022group\u0022 class=\u0022caption caption-img align-center\u0022\u003E\n\u003Ca href=\u0022mailto:hello@magnetgroup.co.za?subject=Electrical Enquiry\u0022\u003E\u003Cimg alt=\u0022Schneider Vigirex\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u00229a5bed0f-9cad-4f86-87f1-60c95bc9f4c6\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/Schneider%20Vigirex.JPG\u0022 /\u003E\u003C/a\u003E\n\u003Cfigcaption\u003EEssential components of a RCM system\u003C/figcaption\u003E\n\u003C/figure\u003E\n\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u00A0\u003C/p\u003E\n\u003Cp\u003EConsidering an \u003Ca href=\u0022https://www.magnetgroup.co.za/solutions-electrical/index.php\u0022\u003E\u003Cstrong\u003ERCM solution\u003C/strong\u003E\u003C/a\u003E for your facility?\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za?subject=Electrical Enquiry\u0022\u003E\u003Cstrong\u003ECHAT\u003C/strong\u003E\u003C/a\u003E to us now!\u003C/p\u003E\n", "created": "May 2021", "terms": "Electrical, Education" }, { "title": "Confused about what Back-Up Power Solution is for You? ", "nid": "508", "body": "\u003Cp\u003EYou\u0027re probably well-aware that the power instability issue in our country is likely not to be resolved in the near future. This in mind, you may want to consider a Back-Up Power solution...\u003C/p\u003E\n\u003Cp\u003EFortunately, this doesn\u0027t have to be an intimidating decision - just follow these simple steps:\u00A0\u003C/p\u003E\n\u003Cp\u003E1. Use our \u003Ca href=\u0022https://shop.magnet.co.za/loadshedding-calculator.html\u0022\u003E\u003Cb\u003ELOAD CALCULATOR\u003C/b\u003E\u00A0\u003C/a\u003Eto determine the load you need to back-up\u003C/p\u003E\n\u003Cp\u003E2. Visit\u003Cb\u003E\u00A0\u003C/b\u003Ethe \u003Ca href=\u0022https://shop.magnet.co.za/loadshedding-calculator.html#!category/energy\u0026amp;id=5C53CB36-CCFA-45DC-9E34-A211F4E73337\u0022\u003E\u003Cstrong\u003EM\u003C/strong\u003E\u003C/a\u003E\u003Cb\u003E\u003Ca href=\u0022https://shop.magnet.co.za/loadshedding-calculator.html#!category/energy\u0026amp;id=5C53CB36-CCFA-45DC-9E34-A211F4E73337\u0022\u003EAGNET STORE\u003C/a\u003E\u00A0\u003C/b\u003Eto\u00A0view the solutions we have to offer.\u003C/p\u003E\n\u003Cp\u003E3.\u00A0\u003Ca href=\u0022https://www.magnet.co.za/contactus.html\u0022\u003E\u003Cstrong\u003ECHAT\u003C/strong\u003E\u003C/a\u003E\u00A0to us, we\u2019re here to help you decide on a system that\u2019s right for your specific application.\u003C/p\u003E\n\u003Cp\u003E\u00A0\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za?subject=Back Up Power Enquiry\u0022\u003E\u003Cimg alt=\u0022back up \u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u002261158f1f-2e56-4f53-ac0d-900c400fa8d3\u0022 height=\u0022146\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/2.jpg\u0022 width=\u0022485\u0022 class=\u0022align-center\u0022 /\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Cp\u003E\u00A0\u003C/p\u003E\n", "created": "Jun 2021", "terms": "Back-Up Power, Education, Products" }, { "title": "PRODUCT NEWS | Schneider\u0026#039;s Compact NSXm MCCB", "nid": "500", "body": "\u003Cp\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za?subject=Schneider Enquiry\u0022\u003E\u003Cimg alt=\u0022Compact NSXm MCCB\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u0022b4b49c55-fe28-47ce-87bc-8b0c2c7a59b5\u0022 height=\u0022300\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/NSXm%20MCCB.jpg\u0022 width=\u0022533\u0022 class=\u0022align-center\u0022 /\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EA new, smaller-sized moulded case circuit breaker (MCCB) is now available.\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/solutions-electrical/index.php\u0022\u003E\u003Cstrong\u003ESchneider Electric\u0027s\u00A0\u003C/strong\u003E\u003C/a\u003EComPact NSXm MCCB is the smallest and newest addition to our range of Schneider Electric products.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003ESpecifications of the ComPact NSXm MCCB are:\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli\u003ENew smaller frame size\u003C/li\u003E\n\u003Cli\u003EDimensions: width 81 mm, height 137 mm, depth 80 mm\u003C/li\u003E\n\u003Cli\u003EFlexible installation - \u00A0can be fitted in any position, switchboard or wall-mounted\u003C/li\u003E\n\u003Cli\u003ENominal current: 16 A to 160 A\u003C/li\u003E\n\u003Cli\u003EFive breaking capacities: 16 kA, 25 kA, 36 kA, 50 kA, 70 kA at 415 V\u003C/li\u003E\n\u003Cli\u003EIntegrated earth leakage protection by means of MicroLogic Vigi earth leakage circuit breaker\u003C/li\u003E\n\u003Cli\u003EThermal-magnetic protection\u003C/li\u003E\n\u003Cli\u003EBuilt\u2011in DIN rail and plate mount capability\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp\u003E\u003Cstrong\u003EBenefits of the\u00A0unit include:\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli\u003EFlexible installation\u003C/li\u003E\n\u003Cli\u003ESaves space as a result of vertical plate mounting\u003C/li\u003E\n\u003Cli\u003EEverLink is an innovative cable connection method with patented creep-compensating technology that is built directly into the terminal\u200B\u003C/li\u003E\n\u003Cli\u003EIntegrated earth leakage protection is now available in the MCCB frame size \u200B\u003C/li\u003E\n\u003Cli\u003EField-installable accessories and one-click auxiliaries \u200B\u003C/li\u003E\n\u003Cli\u003EAuxiliaries are visible through flags and a window\u003C/li\u003E\n\u003Cli\u003ESuited to all standard applications, including: \u200B\u003C/li\u003E\n\u003Cli\u003EStandard applications in industry, building and infrastructure\u200B\u003C/li\u003E\n\u003Cli\u003ELow\u2011voltage switchboards (as feeder in drawers) for power control centers\u200B\u003C/li\u003E\n\u003Cli\u003ELow\u2011voltage panel boards (as incomer) or sub-panel boards (as feeder)\u003C/li\u003E\n\u003Cli\u003EMachines (as incomer) \u2014 HVAC, packaging, lifting, pumping, conveying\u200B\u003C/li\u003E\n\u003Cli\u003EControl panels \u2014 water treatment, tunnel, in-automation solutions\u200B\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp\u003EWe are the largest distributor\u00A0of Schneider Electric products in South Africa and boast\u00A0in-depth Schneider product knowledge and technical expertise.\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za?subject=Schneider Enquiry\u0022\u003E\u003Cstrong\u003ECHAT\u003C/strong\u003E\u003C/a\u003E to us for a Schneider solution for your facility!\u003C/p\u003E\n", "created": "May 2021", "terms": "Electrical, Products, Schneider" }, { "title": "PRODUCT NEWS | Eaton\u0026#039;s M22 Series Pilot Devices", "nid": "499", "body": "\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003EEaton\u2019s M22 Pilot Devices - Proven and Versatile\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003E\u003Cimg alt=\u0022Eaton M22\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u002298cfb2d6-524b-4da6-a2e1-d80490654daa\u0022 height=\u0022158\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/Eaton%20M22.png\u0022 width=\u0022776\u0022 class=\u0022align-center\u0022 /\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EOur extensive range of \u003Ca href=\u0022https://www.magnetgroup.co.za/solutions-electrical/index.php\u0022\u003E\u003Cstrong\u003EEaton products and solutions\u003C/strong\u003E\u003C/a\u003E includes the M22 series Pilot Devices. These 22 mm pilot devices combine an attractive appearance and modular functionality. The M22 series is a full line of pilot devices with features specifically designed for OEMs and panel builders.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003EFeatures:\u003C/strong\u003E\u003Cbr /\u003E\n\u003Cstrong\u003E\u003Cem\u003E1.\u00A0Ease of use\u003C/em\u003E\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EThe M22 uses a conventional mounting nut for fast, easy, secure installation. The mounting adapter snaps to the back of operators without the use of tools. Contact blocks and light units are available with spring-cage terminations for faster, secure, and vibration resistant wiring connections. M22 operators include a moulded sealing gasket and an oversized anti-rotation nib that holds operators firmly in place without twisting or slack.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003E\u003Cem\u003E2. Flexibility and modularity\u003C/em\u003E\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EThe M22 line has field-convertible pushbuttons and field-convertible selector switches (from momentary to maintained operation and selectable key removable positions). In addition, the M22 E-Stop operators were designed with the correct \u201Ctravel to operate contacts\u201D so that they can be used with Eaton\u2019s miniature limit switches. Contact blocks are stackable, and two LED light units provide a range of 12\u201330 Vac/dc and 85\u2013264 Vac.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003E\u003Cem\u003E3. Safety and security\u003C/em\u003E\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EM22 E-Stops are compliant with the ISO/EN 13850 machinery standards and has self-monitoring contact blocks available.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003E\u003Cem\u003E4. Aesthetics and ergonomics\u003C/em\u003E\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EThe M22 series is a low-profile design with compact integrated LED light units. These LED light units utilize sophisticated technology and manufacturing to embed the electrical connections directly into the moulded housing and thereby eliminate the need for a printed circuit board. Finally, the selector switches have very good positive detent feel so that inadvertent switching is unlikely.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EWe are a Premium Distributor of Eaton products in South Africa and boast\u00A0in-depth product knowledge and technical expertise.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za?subject=Eaton Enquiry\u0022\u003E\u003Cstrong\u003ECHAT\u003C/strong\u003E\u003C/a\u003E to us for advice on an Eaton solution for your facility!\u003C/p\u003E\n", "created": "May 2021", "terms": "Electrical, Products, Eaton" }, { "title": "PRODUCT NEWS | Schneider\u0026#039;s TeSys T Motor Management System", "nid": "498", "body": "\u003Cp\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/solutions-electrical/videos.html#Schneider\u0022\u003E\u003Cimg alt=\u0022Tesys T\u0022 data-entity-type=\u0022file\u0022 data-entity-uuid=\u0022e1cc5e41-1a42-468f-8635-288c99a59477\u0022 height=\u0022301\u0022 src=\u0022/cms/drupal8-magnetgroup/sites/default/files/inline-images/1508_TeSys%20T.JPG\u0022 width=\u0022301\u0022 class=\u0022align-center\u0022 /\u003E\u003C/a\u003E\u003C/p\u003E\n\u003Ch2\u003E\u003Cstrong\u003EAdvanced monitoring control and protection of electrical motors\u003C/strong\u003E\u003C/h2\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Ca href=\u0022https://www.magnetgroup.co.za/solutions-electrical/index.php\u0022\u003E\u003Cstrong\u003ESchneider Electric\u0027s\u003C/strong\u003E\u003C/a\u003E TeSys T is a smart motor management system. When associated with a short circuit protection device and a contactor, the device provides full motor monitoring, control and protection for electrical motors.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003E\u003Cstrong\u003EFeatures:\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EThe TeSys T motor management system provides protection, metering and monitoring functions for single-phase and 3-phase AC motors up to 1000 A.\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003ETeSys T is a smart system that can be adapted to any customer request with Custom Logic and is natively connected to any PLC on 6 protocols.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003EThe range is comprised of three components:\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EMain Controller: provides current based protection and monitoring, communication, control and statistics features.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EOptional expansion module: adds voltage, power and energy measurement\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EHMI: a flexible option to quickly monitor and commission a TeSys T system. Control features are also available through the HMI\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp\u003E\u003Cstrong\u003EBenefits:\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003ETeSys T is a compact, smart and easy to select product that can be fully integrated in any automation system or connected to any PLC of the market.\u00A0Advanced protections, monitoring and pre alarming will dramatically increase process availability (less downtime) and reduce operation costs.\u003C/p\u003E\n\u003Cp\u003E\u003Cstrong\u003E1. Flexibility\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EFully open, it communicates with Ethernet protocols: Modbus/TCP and EtherNet/IP, Modbus, CANopen, DeviceNet, PROFIBUS DP protocols.\u00A0\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EDesigned to fit in IEC and NEMA MCC , it integrates 10 predefined control schemes and one custom mode that let adapt control mode, product behavior and even protections to any requests.\u00A0\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003ETeSys T can be controlled through its terminal strip, HMI or communication port. Having a central control in TeSys T will reduce the complexity of your installation, reduce the need of auxiliary equipment, save space and reduce costs.\u00A0\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EFully integrated into Blokset, Okken and Model 6 iPMCC TVDA, Advantys STB solution and in the Foxboro DCS.\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp\u003E\u003Cstrong\u003E2. Trust\u00A0\u00A0\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003ETeSys T is quickly becoming a worldwide standard thanks to its flexibility. Lots of customers in Metal/Mining/Mineral, Oil \u0026amp; Gas, Water Wastewater and other types of applications trust TeSys T to deliver.\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003ETeSys T is highly reliable and has a very long product life thanks to a state-of-the-art component selection (FRAM memory, Flexrigid PCB, etc.) to the all-in- one design and advanced electronic protection.\u00A0\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003ETeSys T Ethernet version enjoys daisy chain loop for higher redundant system.\u00A0\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp\u003E\u003Cstrong\u003E3. Prediction and Energy Management\u00A0\u003C/strong\u003E\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003ETeSys\u00A0is able to accurately monitor current, voltage and power over a wide range and features advanced protection and warning functions. This accuracy is key for an effective protection and preventive maintenance.\u00A0\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EThe advanced protection and warning functions will allow TeSys T to predict process shutdowns and manage processes more efficiently.\u00A0\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003EThe power monitoring capabilities makes TeSys T a green motor management system because it can help to better manage energy consumption.\u00A0\u003C/li\u003E\n\u003Cli class=\u0022text-align-justify\u0022\u003ETeSys T is fully integrated in Powerlogic systems to fully utilize its power and energy monitoring capabilities.\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp\u003E\u00A0\u003Cstrong\u003EApplications:\u003C/strong\u003E\u003C/p\u003E\n\u003Cp class=\u0022text-align-justify\u0022\u003EThe TeSys T range is designed for the management of critical processes in harsh environment for applications such as:\u003C/p\u003E\n\u003Cul\u003E\n\u003Cli\u003EWater Wastewater\u00A0\u003C/li\u003E\n\u003Cli\u003EOil \u0026amp; Gas\u00A0\u003C/li\u003E\n\u003Cli\u003EChemical\u003C/li\u003E\n\u003Cli\u003EMining and Mineral\u00A0\u003C/li\u003E\n\u003Cli\u003EMetals\u00A0\u003C/li\u003E\n\u003Cli\u003EFood \u0026amp; Beverage\u00A0\u003C/li\u003E\n\u003Cli\u003EPharmaceutical\u003C/li\u003E\n\u003Cli\u003ETransportation\u003C/li\u003E\n\u003C/ul\u003E\n\u003Cp\u003E\u003Cstrong\u003EWe are the largest distributor of Schneider Electric in South Africa!\u003C/strong\u003E\u003C/p\u003E\n\u003Cp\u003E\u003Ca href=\u0022mailto:hello@magnetgroup.co.za?subject=Schneider Enquiry\u0022\u003E\u003Cstrong\u003ECHAT\u003C/strong\u003E\u003C/a\u003E to us for a Schneider solution for your facility!\u003C/p\u003E\n", "created": "May 2021", "terms": "Electrical, Products, Schneider" } ]

LEARN | Condition Monitoring pt 5 - Residual Current Monitoring

RCM
Residual Current Monitoring in an Industrial Environment We're wrapping up our series on Condition Monitoring, by discussing Residual Current Monitoring (RCM) as an essential system to implement in any industrial environment. By monitoring the state of the electrical system in a facility, RCM assists in detecting faults early – reducing downtime and saving money. Catch up on previous articles in our Condition Monitoring series: Part 1:The benefits of a condition monitoring system    Part 2: Vibration monitoring Part 3: Vibration monitoring continued Part 4: An overview of motor circuit analys...
Read More >>

Confused about what Back-Up Power Solution is for You?

back up
You're probably well-aware that the power instability issue in our country is likely not to be resolved in the near future. This in mind, you may want to consider a Back-Up Power solution... Fortunately, this doesn't have to be an intimidating decision - just follow these simple steps:  1. Use our LOAD CALCULATOR to determine the load you need to back-up 2. Visit the MAGNET STORE to view the solutions we have to offer. 3. CHAT to us, we’re here to help you decide on a system that’s right for your specific application.     ...
Read More >>

PRODUCT NEWS | Schneider's Compact NSXm MCCB

Compact NSXm MCCB
A new, smaller-sized moulded case circuit breaker (MCCB) is now available. Schneider Electric's ComPact NSXm MCCB is the smallest and newest addition to our range of Schneider Electric products. Specifications of the ComPact NSXm MCCB are: New smaller frame size Dimensions: width 81 mm, height 137 mm, depth 80 mm Flexible installation -  can be fitted in any position, switchboard or wall-mounted Nominal current: 16 A to 160 A Five breaking capacities: 16 kA, 25 kA, 36 kA, 50 kA, 70 kA at 415 V Integrated earth leakage protection by means of MicroLogic Vigi earth leakage circuit breaker Therm...
Read More >>

PRODUCT NEWS | Eaton's M22 Series Pilot Devices

Eaton M22
Eaton’s M22 Pilot Devices - Proven and Versatile Our extensive range of Eaton products and solutions includes the M22 series Pilot Devices. These 22 mm pilot devices combine an attractive appearance and modular functionality. The M22 series is a full line of pilot devices with features specifically designed for OEMs and panel builders. Features: 1. Ease of use The M22 uses a conventional mounting nut for fast, easy, secure installation. The mounting adapter snaps to the back of operators without the use of tools. Contact blocks and light units are available with spring-cage terminations for f...
Read More >>

PRODUCT NEWS | Schneider's TeSys T Motor Management System

Tesys T
Advanced monitoring control and protection of electrical motors Schneider Electric's TeSys T is a smart motor management system. When associated with a short circuit protection device and a contactor, the device provides full motor monitoring, control and protection for electrical motors. Features: The TeSys T motor management system provides protection, metering and monitoring functions for single-phase and 3-phase AC motors up to 1000 A. TeSys T is a smart system that can be adapted to any customer request with Custom Logic and is natively connected to any PLC on 6 protocols. The range is c...
Read More >>

X

Stay informed! Subscribe and receive our weekly newsletter on the latest industry trends, technology and tools of the trade.

SUBSCRIBE